Email Alerts

Email alerts can be dispatched automatically when a significant error occurs.

Configuring Email Alerts

Only Full Administrators and Cluster Administrators can configure alerts.

The email-alert system works by sending an email directly to a configured SMTP server. Each alert email is sent to the configured list of email recipients, to highlight specific issues and problems. Alerts are provided as a popup within Couchbase Web Console.

It is important to ensure that all Couchbase Server nodes have network access to the configured SMTP server.

You can define the settings using Couchbase Web Console, or using the REST API.

The Email Alerts screen appears as follows:

settings alerts

To set up email alerts using Couchbase Web Console, first, select the Enable email alerts check box, to enable the email-alerts configuration. Then, enter appropriate data into the fields listed below.

Email Server Settings

Option Description

Host

The hostname of the SMTP server that will be used to send the email.

Port

The TCP/IP port to be used to communicate with the SMTP server. The default is the standard SMTP port 25.

Username

For email servers that require a username and password to send email, the username is used for authentication.

Password

For email servers that require a username and password to send email, the password is used for authentication.

Require encryption (TLS)

Enable Transport Layer Security (TLS) when sending the email through the designated server.

Email Settings

Option Description

Sender Email

The email address identified as a source from which the email is sent. This email address should be one that is valid as a sender address for the SMTP server that you specify.

Recipients

A list of the recipients of each alert message. To specify more than one recipient, separate each address by a space, comma (,), or semicolon (;).

Test Mail

Click Send Test Email to send a test email to confirm the settings and configuration of the email server and recipients.

Available Alerts

You can enable individual alert messages that can be sent by selecting the appropriate check boxes. The supported alerts are:

Alert Description Code

Node was auto-failed-over

The sending node has been failed over automatically.

auto_failover_node

Maximum number of auto-failed-over nodes was reached

The auto-failover system stops auto-failover when the maximum number of spare nodes available has been reached.

auto_failover_maximum_reached

Node wasn’t auto-failed-over as other nodes are down at the same time

Auto-failover does not take place if there is already a node down.

auto_failover_other_nodes_down

Node was not auto-failed-over as there are not enough nodes in the cluster running the same service

You cannot support auto-failover with less than three nodes.

auto_failover_cluster_too_small

Node was not auto-failed-over as auto-failover for one or more services running on the node is disabled

Auto-failover does not take place on a node as one or more services running on the node is disabled.

auto_failover_disabled

Node’s IP address has changed unexpectedly

The IP address of the node has changed, which may indicate a network interface, operating system, or other network or system failure.

ip

Disk space used for persistent storage has reach at least 90% of capacity

The disk device configured for storage of persistent data is nearing full capacity.

disk

Metadata overhead is more than 50%

The amount of data required to store the metadata information for your dataset is now greater than 50% of the available RAM.

overhead

Bucket memory on a node is entirely used for metadata

All the available RAM on a node is being used to store the metadata for the objects stored. This means that there is no memory available for caching values. With no memory left for storing metadata, further requests to store data will also fail.

Only applicable to buckets configured for value-only ejection. See Ejection, for information.

ep_oom_errors

Writing data to disk for a specific bucket has failed

The disk or device used for persisting data has failed to store persistent data for a bucket.

ep_item_commit_failed

Writing event to audit log has failed

The audit log event writing has failed.

audit_dropped_events

Approaching full Indexer RAM warning

The indexer RAM limit threshold is approaching warning.

indexer_ram_max_usage

Remote mutation timestamp exceeded drift threshold

The remote mutation timestamp exceeded drift threshold warning.

ep_clock_cas_drift_threshold_exceeded

Communication issues among some nodes in the cluster

There are some communication issues in some nodes within the cluster.

communication_issue